FLUID 21XX e-Fair  Navigation : EXPO21XX.com Home > FLUID 21XX > e-Hall > HONSBERG
 
Home Register your company About us Contact us
Home back to hall map back to hall   
Go to Search Go to Search
      A      
 
4
A4    Germany HONSBERG
 
 
 
 Show Screen  
 

  
 Offer Profile  
As a developer and manufacturer of mechanical and electronic metering and control equipment we want to offer solutions for your applications or make new designs for your requirements. Trust in our longtime experience with the general industrial machine and plant engineering as well as for specific areas concerning process technology and mining.
 Product Abstract  
Flow
Piston Valve Design
 
Piston Inline Design
 
Variable Area
 
Paddle
Dynamic Flap
 
Rotor
 
Turbine
 
Gear Wheel
Oval Wheel
 
Calorimetric
 
Inductive
 
Ultrasonic
Vortex
 
Sight Glass
 
Flap
 
Sphere
Orifice
           
Level
NM
Appliance:
level, float control
top assembly
Electr. Data:
reed switch n.o. / n.c.
250-300 V AC 0,5-1,3A 10-80 VA
Basic Data:
PN 5-40 , tmax=60-105°C
Connection:
Pg7 male thread socket plastic
G1/8A - G1/4A male thread socket stainless steel
Height:
40-75mm
 
NMS
Appliance:
level, float control
top assembly
Electr. Data:
reed switch n.o. / n.c.
250-300 V AC 0,5-1,3A 50-80 VA
Basic Data:
PN 12 , tmax=105°C
Connection:
G1/8A male thread socket brass
Height:
40-77mm
 
SB
Appliance:
level, float control
top assembly
Electr. Data:
reed switch change over
220 V AC 0.5 A 60 VA
Basic Data:
PN 12 , tmax=105°C
Connection:
G1A male thread socket brass
Height:
100-500mm
 
NR
Appliance:
level, float control
top assembly
Electr. Data:
reed switch n.o. / n.c.
250 V AC 1 A 250 VA
Basic Data:
PN 15 , tmax=100°C
Connection:
G2A male thread socket stainless steel
DN100 flange aluminium
Height:
250-1000mm
LC
Appliance:
level, float measure
top assembly
Electr. Data:
resistance chain 24 V DC 50mA
opional 4...20mA or 0...10V
Basic Data:
PN 10-40 , tmax=105°C
Connection:
G1A - G1 1/2 A male thread socket brass
G2A male thread socket stainless steel
Height:
250-2000mm
 
RW
Appliance:
level, float control
wall assembly
Electr. Data:
reed switch n.o. / n.c.
220-250 V AC 0.28-0.5 A 30-50 VA
Basic Data:
PN 5-6 , tmax=120-200°C
Connection:
1/2BSP male thread socket stainless steel
Depth:
80-89mm
 
RWI
Appliance:
level, float control
wall assembly
Electr. Data:
reed switch n.o. / n.c.
250 V AC 0.5 A 50 VA
Basic Data:
PN 3-6 , tmax=90-130°C
Connection:
M16 male thread socket plastic
23 compression gland plastic
Depth:
60mm
 
NW3
Appliance:
level, float control
wall assembly
Electr. Data:
reed switch n.o. / n.c.
230 V AC 1A 50 VA
Basic Data:
PN 10-25 , tmax=110°C
Connection:
G3/4A male thread socket brass / stainless steel
Depth:
72-76mm
NW1
Appliance:
level, float control
wall assembly
Electr. Data:
reed switch n.o. / n.c.
230 V AC 1A 50 VA
Basic Data:
PN 10-25 , tmax=110°C
Connection:
G3/4A male thread socket brass / stainless steel
Depth:
72-76mm
 
MW3
Appliance:
level, float control
wall assembly
Electr. Data:
micro switch change over
250 V AC 5 A
Basic Data:
PN 10-25 , tmax=110°C
Connection:
G3/4A male thread socket brass / stainless steel
Depth:
72-76mm
 
CWE
Appliance:
level, float control
wall assembly
Electr. Data:
micro switch change over
250 V AC 15(8) A
Basic Data:
PN 11 , tmax=85°C
Connection:
R1" male thread socket brass
Depth:
190mm
 
MWI
Appliance:
level, float control
wall assembly
Electr. Data:
micro switch change over
250 V AC 5 A
Basic Data:
PN 15 , tmax=180°C
Connection:
G1A male thread socket brass
Depth:
220mm
NG
Appliance:
level, float control
bypass assembly
Electr. Data:
reed switch n.o. / change over
220 V AC 0.2 A
Basic Data:
PN 8 , tmax=75°C
Connection:
1/2"NPT female thread aluminium
Hole Center Distance:
110-167mm
 
NBS
Appliance:
level, float indicate
top assembly
Basic Data:
tmax=50°C
Connection:
G3/8A male thread brass
Height:
185-445mm
 
NB
Appliance:
level, sight glass indicate
top assembly
Basic Data:
tmax=80°C
Connection:
G3/8A male thread brass
Height:
40-300mm
 
NA
Appliance:
level, sight glass indicate
wall assembly
Basic Data:
tmax=80°C
Connection:
G3/8A male thread brass
Height:
40-300mm
NL
Appliance:
level, infrared control
Electr. Data:
supply 5 or 12 V DC
transistor output
Basic Data:
tmax=100°C
Connection:
1/2" NPT male thread socket steel / stainless steel
 
EL
Appliance:
level, ultrasonic measure
Electr. Data:
supply 18...30 V DC
output 0...10V
Basic Data:
tmax=90°C
Connection:
M18x1 / M30x1,5 male thread socket plastic
Range:
100-2500mm
       
Temperature
TF1
Principle:
control
Electr. Data:
n.o. / n.c.
230 V AC 10 A
Basic Data:
PN 100 , tmax=100-140°C
Connection:
G1/2A male thread socket brass
Range:
50-90°C
 
TR
Principle:
control
Electr. Data:
change over
250 V AC 15(8) A
Basic Data:
PN 16 , tmax=145°C
Connection:
R1/2" male thread socket brass
Range:
35-130°C
 
ETS
Principle:
measure
Electr. Data:
supply 10...30 V DC
output 4...20 mA
Basic Data:
PN 25 , tmax=80°C
Connection:
G1/2A male thread socket stainless steel
Range:
0-100°C
 
ETSD
Principle:
differential measure
Electr. Data:
supply 10...30 V DC
output 4...20 mA
Basic Data:
PN 25 , tmax=80°C
Connection:
G1/2A male thread socket stainless steel
Range:
0-50°C
Pressure
PM
Principle:
control
Electr. Data:
n.o. / n.c.
48 V AC 0.5(0.2)A
Basic Data:
PN 80-300 , tmax=60°C
Connection:
R1/8" male thread socket brass / steel / stainless steel
Range:
0.15 - 150 bar rel
 
PH
Principle:
control
Electr. Data:
n.o. / n.c.
48 V AC 0.5(0.2)A
Basic Data:
PN 80-300 , tmax=60°C
Connection:
R1/8" male thread socket brass / steel / stainless steel
Range:
0.15 - 150 bar rel
 
PI
Principle:
control
Electr. Data:
change over
250 V AC 3(2)A
Basic Data:
PN 60-600 , tmax=60°C
Connection:
R1/8" - R1/4" male thread socket aluminium
Range:
0.2 - 300 bar rel
 
VP
Principle:
control
Electr. Data:
n.o. / n.c.
48 V AC 0.5(0.2)A
Basic Data:
PN 20 , tmax=60°C
Connection:
R1/8" male thread socket steel / stainless steel
Range:
200-900 mbar
MD
Principle:
differential control
Electr. Data:
change over
250 V AC 5(0.5)A ,
24 V AC 1(0.2)A
Basic Data:
PN 0.15-0.3 , tmax=80°C
Connection:
6.2 nozzle plastic
Range:
0.2 - 10 mbar rel
 
PS
Principle:
measure
Electr. Data:
supply 11.5...30 V DC
output 4-20 mA
Basic Data:
PN 16-200 , tmax=125°C
Connection:
G1/4A male thread socket stainless steel
Range:
0-100 bar
 
EPS
Principle:
measure
Electr. Data:
supply 10...30 V DC
output 4...20 mA
Basic Data:
PN 1-400 , tmax=80°C
Connection:
G1/2A male thread socket stainless steel
Range:
0-400 bar
 
EPS1
Principle:
measure
Electr. Data:
supply 10...30 V DC
output 4...20 mA
Basic Data:
PN 1-400 , tmax=80°C
Connection:
G1/2A male thread socket stainless steel
Range:
0-200 bar
EPD1
Principle:
differential measure
Electr. Data:
supply 10...30 V DC
output 4...20 mA
Basic Data:
PN 3-400 , tmax=80°C
Connection:
G1/2A male thread socket stainless steel
Range:
0-200 bar
           
Integrated Systems
Omni
  • two switching points
  • hysteresis selectable in magnitude and direction
  • 4(0) – 20mA analogue output
  • graphical LCD display (increased temperature range, illuminated, units in the display, incl. super-bright signalling LED)
  • dialogue messages in the display
  • programming ring (can be operated when wearing protective gloves)
  • programming protection by turning through 180° or by removing
  • programming ring
  • stainless steel housing
  • mineral glass (tempered, scratch and breakage proof) for covering the display
  • M12x1 connector system
  • system mounting to all HONSBERG primary sensors (rotatable)
  • compact dimensions
  • IP 67
 
Flex
  • 4-20 mA or 0-10 V output
  • switch or frequency output pnp, npn
  • LED switch indicator surround
  • hysteresis variable
  • switch on delay variable
  • switch off delay variable
  • delay subsequent to supply
  • high level of variation selection
  • easy programming using magnet
  • M12x1 connector system
  • identical handling of different sensors
  • system mounting to all HONSBERG primary sensors (rotatable)
  • stainless steel housing
  • compact dimensions
  • IP 67
       
Converter
A-H1
Principle:
switch head ATEX
I M1 EEx ia I
II 1G EEx ia IIC T4
II 1D EEx iaD 20 T135
Electr. Data:
30V 1.5A 50W change over
Basic Data:
tmax=50°C
 
A-U1
Principle:
switch head ATEX
I M1 EEx ia I
II 1G EEx ia IIC T4
II 1D EEx iaD 20 T135
Electr. Data:
30V 1.5A 50W n.o. or n.c.
Basic Data:
tmax=50°C
 
A-V1
Principle:
switch head ATEX
I M1 EEx ia I
II 1G EEx ia IIC T4
II 1D EEx iaD 20 T135
Electr. Data:
30V 1.5A 50W change over
Basic Data:
tmax=50°C
 
A-V2
Principle:
switch head ATEX
I M1 EEx ia I
II 1G EEx ia IIC T4
II 1D EEx iaD 20 T135
Electr. Data:
30V 1.5A 50W change over
Basic Data:
tmax=50°C
A-V3
Principle:
switch head ATEX
II 2G EEx D IIC T6
Electr. Data:
250V AC 5A change over
Basic Data:
tmax=50°C
 
EEZ-904
Principle:
counter
Electr. Data:
supply 90...260 V AC, 48 V AC , 24 V AC or 11...30 V DC
2 relay with potentalfree make or break contact or optocoupler with open collector and emitter
Basic Data:
tmax=50°C
 
EFFF
Principle:
frequency/frequency converter
Electr. Data:
supply 10...30 V DC
output PNP, NPN or NPN OC
Basic Data:
tmax=70°C
 
EFFI
Principle:
frequency Sensor with current output
Electr. Data:
supply 10...30 V DC
output 0..20 mA or 4..20 mA
Basic Data:
tmax=70°C
EFFS
Principle:
frequency switch
Electr. Data:
supply 10...30 V DC
output PNP, NPN or NPN OC
Basic Data:
tmax=70°C
 
EFFU
Principle:
frequency Sensor with voltage output
Electr. Data:
supply 10...30 V DC
output 0..10 V or 2..10 V
Basic Data:
tmax=70°C
 
ESA1
Principle:
local electronic unit and switching module
Electr. Data:
supply 24 V DC
output n.o. 24 V DC
Basic Data:
tmax=60°C
 
ESK2
Principle:
local electronic with two electronic switching outputs
Electr. Data:
supply 18...30 V DC
electronic , NPN/PNP connectable
Basic Data:
tmax=80°C
ESK3
Principle:
local electronic with two electronic switching outputs
Electr. Data:
supply 230 V AC
output relay contact
Basic Data:
tmax=80°C
 
GIA
Principle:
Display with switching point
Electr. Data:
4...20 mA, two wire
Basic Data:
tmax=50°C
 
MSR
Principle:
multifunctional relay
Electr. Data:
supply 230 V AC
output relay and 24 V DC
Basic Data:
tmax=70°C
 
WE
Principle:
isolated switching amplifier with realay output
intrinsically safe control circuit [EEx ia] IIC
Electr. Data:
supply 198-253 V AC,
45-65 Hz
Basic Data:
tmax=60°C
Filter
ZV
Principle:
magnetic filter
Basic Data:
PN 16, tmax=60°C
Connection:
G1/2 - G3 female thread bronze
 
ZE
Principle:
fine filter
Basic Data:
PN 10, tmax=52°C
Connection:
Rp 1/8 - Rp3/4 female thread plastic
       
Accessories
VB
Principle:
manifold 1-8 Measurement Spots
Basic Data:
PN 25, tmax=110°C
Connection:
G3/4 female thread aluminium
 
VC
Principle:
control valves
Basic Data:
PN 16, tmax=120°C
Connection:
NPT1/8" female thread stainless steel
 
FL
Principle:
flange connection
Connection:
flange DN32 steel/stainless steel
 
TS
Principle:
T-fitting
Connection:
female thread G3/8 to G2 brass/stainless steel
HE
Principle:
spark protector
Electr. Data:
250 V AC 50 Hz; 630 V DC
           
 
 

5
 
   
      C      
Exit the Hall  Exit to Hall HONSBERG   Exit to Hall   Next Corridor 6-10